Chronic co-implantation of ultraflexible neural electrodes and a cranial window

  • Yin R
  • Noble B
  • He F
  • et al.
10Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

Significance: Electrophysiological recording and optical imaging are two prevalent neurotech-nologies with complementary strengths, the combined application of which can significantly improve our capacity in deciphering neural circuits. Flexible electrode arrays can support longitudinal optical imaging in the same brain region, but their mechanical flexibility makes surgical preparation challenging. Here, we provide a step-by-step protocol by which an ultraflexible nanoelectronic thread is co-implanted with a cranial window in a single surgery to enable chronic, dual-modal measurements. Aim: The method uses 1-μm-thick polymer neural electrodes which conform to the site of implantation. The mechanical flexibility of the probe allows bending without breaking and enables long-lasting electrophysiological recordings of single-unit activities and concurrent, high-resolution optical imaging through the cranial window. Approach: The protocol describes methods and procedures to co-implant an ultraflexible electrode array and a glass cranial window in the mouse neocortex. The implantation strategy includes temporary attachment of flexible electrodes to a retractable tungsten-microwire insertion shuttle, craniotomy, stereotaxic insertion of the electrode array, skull fixation of the cranial window and electrode, and installation of a head plate. Results: The resultant implant allows simultaneous interrogation of brain activity both electrophy-siologically and optically for several months. Importantly, a variety of optical imaging modalities, including wide-field fluorescent imaging, two-photon microscopy, and functional optical imaging, can be readily applied to the specific brain region where ultraflexible electrodes record from. Conclusions: The protocol describes a method for co-implantation of ultraflexible neural electrodes and a cranial window for chronic, multimodal measurements of brain activity in mice. Device preparation and surgical implantation are described in detail to guide the adaptation of these methods for other flexible neural implants and cranial windows.

References Powered by Scopus

A quantitative description of membrane current and its application to conduction and excitation in nerve

16350Citations
N/AReaders
Get full text

Millisecond-timescale, genetically targeted optical control of neural activity

3878Citations
N/AReaders
Get full text

Deep tissue two-photon microscopy

3603Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Low-threshold, high-resolution, chronically stable intracortical microstimulation by ultraflexible electrodes

28Citations
N/AReaders
Get full text

Longitudinal neural and vascular recovery following ultraflexible neural electrode implantation in aged mice

10Citations
N/AReaders
Get full text

Flexible high-density microelectrode arrays for closed-loop brain–machine interfaces: a review

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yin, R., Noble, B. C., He, F., Zolotavin, P., Rathore, H., Jin, Y., … Luan, L. (2022). Chronic co-implantation of ultraflexible neural electrodes and a cranial window. Neurophotonics, 9(03). https://doi.org/10.1117/1.nph.9.3.032204

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

67%

Researcher 2

22%

Professor / Associate Prof. 1

11%

Readers' Discipline

Tooltip

Neuroscience 3

38%

Engineering 2

25%

Agricultural and Biological Sciences 2

25%

Chemical Engineering 1

13%

Save time finding and organizing research with Mendeley

Sign up for free