Experimental research on effects of nozzle size intended for water jet impingement cooling

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Rigorous experiments stay performed for examining influences of nozzle size on heat dispersal over flat plate concerning constant thermal value 6 W/cm2. This paper presents the experimental studies on cooling behavior with water jet impingement. Several influencing parameters pertaining to cooling behaviors of striking jets got recognized for investigating impacts over heat transfer characteristics. The parameters taken into account are nozzle diameter (3, 4, 5 and 6 mm), Reynolds number (800, 1600, 2400 and 3200), nozzle to plate spacing (20, 25, 30 and 35 mm) and jet inclination (30°, 45°, 60°, 75° and 90°). Additionally, the studies are limited to a constant heat flux situation. The chary interpretations of results tell that performance remains boosted with regard to these key parameters. Nevertheless, for present experimental settings, nozzle diameter of 5 mm provides sufficient thermal features and is the finest one.

Cite

CITATION STYLE

APA

Kund, N. K. (2019). Experimental research on effects of nozzle size intended for water jet impingement cooling. International Journal of Innovative Technology and Exploring Engineering, 8(12), 1871–1874. https://doi.org/10.35940/ijitee.L2869.1081219