A simple, cost-effective sensor for detecting lead ions inwater using under-potential deposited bismuth sub-layer with differential pulse voltammetry (DPV)

20Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.

Abstract

This research has developed a simple to use, cost effective sensor system for the detection of lead ions in tap water. An under-potential deposited bismuth sub-layer on a thin gold film based electrochemical sensor was designed, manufactured, and evaluated. Differential pulse voltammetry (DPV) measurement technique was employed in this detection. Tap water from the Cleveland, OH, USA regional water district was the test medium. Concentrations of lead ion in the range of 8 × 10-7 M to 5 × 10-4 M were evaluated, showing a good sensitivity over this concentration range. The calibration curve for the DPV measurements of lead ions in tap water showed excellent reproducibility with R2 value of 0.970. This DPV detection system required 3–6 min to complete the detection measurement. A longer measurement time of 6 min was used for the lower lead ion concentration. The selectivity of this lead ion sensor was very good, and Fe III, Cu II, Ni II, and Mg II at a concentration level of 5 × 10-4 M did not interfere with the lead ion measurement.

References Powered by Scopus

Bismuth-coated carbon electrodes for anodic stripping voltammetry

1001Citations
N/AReaders
Get full text

A review on detection of heavy metal ions in water - An electrochemical approach

902Citations
N/AReaders
Get full text

Electrochemistry at Well-Characterized Surfaces

344Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Highly sensitive electrochemical analysis of tunnel structured MnO<inf>2</inf> nanoparticle-based sensors on the oxidation of nitrite

55Citations
N/AReaders
Get full text

A New Class of Low-Temperature Plasma-Activated, Inorganic Salt-Based Particle-Free Inks for Inkjet Printing Metals

35Citations
N/AReaders
Get full text

L-Cysteine peptide-functionalized PEDOT-PSS/rGO nanocomposite for selective electrochemical detection of lead Pb(II) ions

33Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Dai, Y., & Liu, C. C. (2017). A simple, cost-effective sensor for detecting lead ions inwater using under-potential deposited bismuth sub-layer with differential pulse voltammetry (DPV). Sensors (Switzerland), 17(5). https://doi.org/10.3390/s17050950

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 32

76%

Researcher 8

19%

Lecturer / Post doc 2

5%

Readers' Discipline

Tooltip

Chemistry 18

44%

Engineering 13

32%

Materials Science 7

17%

Chemical Engineering 3

7%

Save time finding and organizing research with Mendeley