The purpose of this study is to quantify the discrepancy between optical guidance platform (OGP) frameless localization system (Varian) and Trilogy on-board imaging (OBI) system (Varian) for setting up phantom and stereotactic radiosurgery (SRS) patient; and to determine whether cone-beam CT (CBCT) is necessary for OGP patient setup, and compare CBCT and orthogonal kV-kV in term of their verification capability. Three different phantoms were used in the study: a custom-made phantom, a Penta-Guide phantom, and a RANDO phantom. Five patients using both OGP and CBCT setup and 14 patients using CBCT setup alone were analyzed. One patient who had big couch shifts discrepancy between OGP and CBCT was selected for further investigation. Same patient's CBCT and planning CT were fused. A RANDO phantom simulation experiment was performed using OGP setup with both CBCT and orthogonal kV-kV verification. For all of three phantom experiments, the shifts performed by CBCT beam and orthogonal kV-kV were all within 1 mm. Among five SRS patients using OGP setup, three had 3D couch corrections more than 3 mm. The image fusion of CBCT and planning CT clearly illustrated a tilt of bite-block in a patient's mouth. For 14 SRS patients using CBCT-guided setup, overall 3D correction was 3.3 ± 1.5 mm. RANDO phantom experiment demonstrated how a tilted bite-block caused isocenter shift. CBCT-calculated shifts are the same as expected, but kV-kV results differed by 1-2 mm if the initial head position is tilted. The bite-block tilting in patient's mouth is a major reason for the cause of positioning error for OGP frameless SRS setup. CBCT verification is necessary. CBCT provides more accurate couch corrections than orthogonal kV-kV when head was tilted. OGP is useful for detecting patient movement, but it does not necessarily imply that the isocenter has moved.

References Powered by Scopus

The University of Florida frameless high-precision stereotactic radiotherapy system

160Citations
N/AReaders
Get full text

Image localization for frameless stereotactic radiotherapy

90Citations
N/AReaders
Get full text

A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging

86Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The Mobius AIRO mobile CT for image-guided proton therapy: Characterization & commissioning

18Citations
N/AReaders
Get full text

The clinical feasibility and performance of an orthogonal X-ray imaging system for image-guided radiotherapy in nasopharyngeal cancer patients: Comparison with cone-beam CT

8Citations
N/AReaders
Get full text

eNAL++: A new and effective off-line correction protocol for rotational setup errors when using a robotic couch

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Fu, L., Perera, H., Ying, X., & Yu, Y. (2014). Importance of CBCT setup verification for optical-guided frameless radiosurgery. Journal of Applied Clinical Medical Physics, 15(3), 32–40. https://doi.org/10.1120/jacmp.v15i3.4487

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 19

61%

Researcher 7

23%

Lecturer / Post doc 3

10%

Professor / Associate Prof. 2

6%

Readers' Discipline

Tooltip

Medicine and Dentistry 26

63%

Physics and Astronomy 10

24%

Nursing and Health Professions 4

10%

Agricultural and Biological Sciences 1

2%

Save time finding and organizing research with Mendeley

Sign up for free