Prevalence of abnormal findings when adopting new national and international Global Lung Function Initiative reference values for spirometry in the Finnish general population

  • Kainu A
  • Lindqvist A
  • Sovijärvi A
N/ACitations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND New Finnish (Kainu2015) and international Global Lung Function Initiative (GLI2012) reference values for spirometry were recently published. The aim of this study is to compare the interpretative consequences of adopting these new reference values with older, currently used Finnish reference values (Viljanen1982) in the general population of native Finns. METHODS Two Finnish general population samples including 1,328 adults (45% males) aged 21-74 years were evaluated. Airway obstruction was defined as a reduced ratio of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), possible restrictive pattern as reduced FVC, and decreased ventilatory capacity as reduced FEV1 below their respective 2.5th percentiles. The severity gradings of reduced lung function were also compared. RESULTS Using the Kainu2015 reference values, the prevalence of airway obstruction in the population was 5.6%; using GLI2012 it was 4.0% and with Viljanen1982 it was 13.0%. Possible restrictive pattern was found in 4.2% using the Kainu2015 values, in 2.0% with GLI2012, and 7.9% with the Viljanen1982 values. The prevalence of decreased ventilatory capacity was 6.8, 4.0, and 13.3% with the Kainu2015, GLI2012 and Viljanen1982 values, respectively. CONCLUSIONS The application of the GLI2012 reference values underestimates the prevalence of abnormal spirometric findings in native Finns. The adoption of the Kainu2015 reference values reduces the prevalences of airways obstruction, decreased ventilatory capacity, and restrictive impairment by approximately 50%. Changing from the 2.5th percentile, the previously used lower limit of normal, to the 5th percentile recommended by the American Thoracic Society/European Respiratory Society will not increase the prevalence of abnormal findings in the implementation of spirometry reference values.

Cite

CITATION STYLE

APA

Kainu, A., Lindqvist, A., & Sovijärvi, A. R. A. (2016). Prevalence of abnormal findings when adopting new national and international Global Lung Function Initiative reference values for spirometry in the Finnish general population. European Clinical Respiratory Journal, 3(1), 30658. https://doi.org/10.3402/ecrj.v3.30658

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free