Background: Clinically optimized focusing of drug administration to specific need of patient with bispectral index (BIS) monitoring results in reduced dose and faster recovery of consciousness. This study was planned with an aim to study and compare the conventional clinical end point or BIS on the requirement of dosage of propofol, hemodynamic effects, and BIS alterations following propofol induction. Methods: 70 patients, ASA I and II, 20-60 years undergoing elective surgical procedure under general anesthesia with endotracheal intubation were selected and divided into two groups. Group A received (inj.) fentanyl (2 μg/kg), followed 3 min later by inj. propofol at the rate of 30 mg/kg/hr infusion till the loss of response to verbal command while group B received inj. fentanyl (2 μg/kg), followed 3 min later by inj. propofol at the rate of 30 mg/kg/hr infusion. The end point of hypnosis was when the BIS value was sustained for 1 min at 48±2. The patients were intubated. Total induction dose of propofol was noted in each group. The value of BIS and hemodynamic parameters (heart rate, systolic/diastolic blood pressure) were noted at the time of loss of consciousness, at the time of intubation, and 1 min after intubation, thereafter every minute for first 10 min and thereafter every 10 min till end of surgery. Any involuntary muscle activity such as jerky movements, dystonic posturing, and opisthotonos were also recorded. Results: The mean dose of propofol used in groups A and B were 1.85±0.48 mg/kg and 1.79±0.41 mg/kg, respectively. The dosage used in group B were less but not clinically significant (P=0.575). On comparing the dosage of propofol in males among the groups there was a significantly lower dosage of propofol required in group B (2.06±0.45 mg/kg and 1.83±0.32 mg/kg, respectively, P=0.016). This decrease however was not seen in female patients dosage being 1.65±0.44 mg/kg and 1.75±0.49 mg/kg, respectively (P=0.372). The hemodynamic variables including heart rate, systolic/diastolic blood pressure and BIS were comparable within the group at induction, post-induction, and intubation. However, there was a significant increase in all the parameters at postintubation readings (P<0.001). Conclusion: No significant difference in the induction dose of propofol was observed when assessed clinically (loss of verbal response) or by BIS monitoring. Traditional teaching to titrate the dose of propofol and depth of anesthesia during intubation by loss of verbal response is as good as BIS value monitoring.

Cite

CITATION STYLE

APA

Clinical Anesthesiology. (2014). Clinical Anesthesiology. Springer New York. https://doi.org/10.1007/978-1-4614-8696-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free