Endocardial vagal atrioventricular node stimulation in humans: Reproducibility on 18-month follow-up

7Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Aims. Control of atrioventricular (AV) node conduction by means of high-frequency stimulation (HFS) of efferent AV node vagal stimulation (AVNS) fibres enables the ventricular rate (VR) to be modulated during atrial fibrillation (AF). The Aims. of this study were to verify, on 18-month follow-up, the reproducibility of the dromotropic effect obtained on implantation and the long-term reliability of the system in patients who received an implantable cardioverter-defibrillator (ICD) with a standard atrial lead positioned at a location suitable for AVNS. Methods and results. We enrolled 12 patients with paroxysmal or persistent AF who were candidates for ICD. The right atrium was mapped to locate the pacing site, and a transvenous screw-in lead was implanted in that region. The voltages required for VR modulation (25 VR reduction) and complete AV block at different pulse durations (from 0.1 to 0.5 ms) were recorded. Eleven out of 12 patients underwent 18-month follow-up examination. Atrial pacing parameters were adequate and did not differ from the baseline values (all P > 0.05): pacing threshold 0.9 ± 0.5 V (0.5 ms pulse duration) and impedance 556 ± 121, with P-wave amplitude of 1.6 ± 0.7 mV. High-frequency stimulation induced VR modulation in nine patients and complete AV block in eight patients at pulse durations ≥0.3 ms. No differences were observed in the voltages for VR modulation and complete AV block between implantation and 18-month examination (all P > 0.100). Conclusion. Ventricular rate control during AF was obtained under HFS 18 months after implantation in patients with the atrial lead positioned at a location suitable for AVNS. The pacing outputs needed to achieve the dromotropic effect were comparable to those measured on implantation. Published on behalf of the European Society of Cardiology. © 2010 The Author.

Cite

CITATION STYLE

APA

Rossi, P., Bianchi, S., Valsecchi, S., Porcelli, D., Sgreccia, F., Lucifiero, A., … Azzolini, P. (2010). Endocardial vagal atrioventricular node stimulation in humans: Reproducibility on 18-month follow-up. Europace, 12(12), 1719–1724. https://doi.org/10.1093/europace/euq343

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free