Research on stress detection technology of long-distance pipeline applying non-magnetic saturation

6Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

In order to study the stress detection method on long-distance oil and gas pipeline, the distribution characteristics of the surface remanence signals in the stress concentration regions must be known. They were studied by using the magnetic domain model in the non magnetic saturation state. The finite element method was used herein with the aim to analyse the static and mechanical characteristics of a ferromagnetic specimen. The variation law of remanence signal in stress concentration regions was simulated. The results show that a residue signal in the stress concentration region exists. In addition, a one-to-one correspondence in the non-magnetic saturation environment is evident. In the case of magnetic saturation, the remanence signal of the stress concentration region is covered and the signal cannot be recognised.

Cite

CITATION STYLE

APA

Liu, B., He, L., Zhang, H., Sfarra, S., Fernandes, H., Perilli, S., & Ren, J. (2019). Research on stress detection technology of long-distance pipeline applying non-magnetic saturation. IET Science, Measurement and Technology, 13(2), 168–174. https://doi.org/10.1049/iet-smt.2018.5404