A new instrument for stable isotope measurements of 13C and 18O in CO2 - Instrument performance and ecological application of the Delta Ray IRIS analyzer

17Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

Abstract

We used the recently developed commercially available Delta Ray isotope ratio infrared spectrometer (IRIS) to continuously measure the CO2 concentration c and its isotopic composition δ13C and δ18O in a managed beech forest in central Germany. Our objectives are (a) to characterize the Delta Ray IRIS and evaluate its internal calibration procedure and (b) to quantify the seasonal variability of c, δ13C, δ18O and the isotopic composition of nighttime net ecosystem CO2 exchange (respiration) R13ecoC and R18ecoO derived from Keeling plot intercepts. The analyzer's minimal Allan deviation (as a measure of precision) was below 0.01 ppm for the CO2 concentration and below 0.03‰ for both δ values. The potential accuracy (defined as the 1σ deviation from the respective linear regression that was used for calibration) was approximately 0.45 ppm for c, 0.24‰ for 13C and 0.3‰ for 18O. For repeated measurements of a target gas in the field, the long-term standard deviation from the mean was 0.3 ppm for c and below 0.3‰ for both δ values. We used measurements of nine different inlet heights to evaluate the isotopic compositions of nighttime net ecosystem CO2 exchange R13ecoC and R18ecoO in a 3-month measurement campaign in a beech forest in autumn 2015. During this period, an early snow and frost event occurred, coinciding with a change in the observed characteristics of both R13ecoC and R18ecoO. Before the first snow, R13ecoC correlated significantly (p < 10-4) with time-lagged net radiation Rn, a driver of photosynthesis and photosynthetic discrimination against 13C. This correlation became insignificant (p > 0:1) for the period after the first snow, indicating a decoupling of δ13C of respiration from recent assimilates. For 18O, we measured a decrease of 30‰ within 10 days in R18ecoO after the snow event, potentially reflecting the influence of 18O depleted snow on soil moisture. This decrease was 10 times larger than the corresponding decrease in δ18O in ambient CO2 (below 3 ‰) and took 3 times longer to recover (3 weeks vs. 1 week). In summary, we conclude that (1) the new Delta Ray IRIS with its internal calibration procedure provides an opportunity to precisely and accurately measure c, δ13C and δ18O at field sites and (2) even short snow or frost events might have strong effects on the isotopic composition (in particular 18O) of CO2 exchange on an ecosystem scale.

Cite

CITATION STYLE

APA

Braden-Behrens, J., Yan, Y., & Knohl, A. (2017). A new instrument for stable isotope measurements of 13C and 18O in CO2 - Instrument performance and ecological application of the Delta Ray IRIS analyzer. Atmospheric Measurement Techniques, 10(11), 4537–4560. https://doi.org/10.5194/amt-10-4537-2017

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free