A study on the practical use of a task and ambient lighting system in an office

17Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

The possibility of the practical use as an office lighting system, which make the total illuminance of 4001x and Task and Ambient illuminance ratio of 1.0 on the working desk, by using Task and Ambient Lighting system was reported on the last year research. On this year research, the following aspects were indicated based on the analysis of the psychological queries after two weeks actual work in the specific illuminance level and Task and Ambient illuminance ratio. The illuminance level of 2001x on a working desk cause some psychological problem as room and desk area 'darkness' and illuminance level 'unevenness'. These problems were improved when the illuminance level of 3001x was applied. And this analysis suggested that the Task and Ambient illuminance ratio shall be around 1.0. An approximately 20% saving energy can be achieved under this lighting system condition compared with the general office lighting system. Copyright © 2007 The Illuminating Engineering Institute of Japan.

Cite

CITATION STYLE

APA

Yamakawa, K., Watabe, K., Inanuma, M., Sakata, K., & Takeda, H. (2000). A study on the practical use of a task and ambient lighting system in an office. Journal of Light and Visual Environment, 24(2). https://doi.org/10.2150/jlve.24.2_15