5-year serial follow-up of clinical condition and ventricular function in patients after repair of tetralogy of Fallot

26Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective To study the changes over time in biventricular size and function, and clinical parameters in patients after repair of tetralogy of Fallot (TOF) without subsequent pulmonary valve replacement (PVR). Methods We prospectively included 78 non-PVR patients (age 20(6-60)years at baseline), who were studied twice with a 5-year interval. Patients underwent magnetic resonance imaging for assessment of biventricular size and function. Exercise testing and electrocardiography were performed to determine peak oxygen uptake (peak VO2) and QRS duration. N-terminal prohormone brain natriuretic peptide (NT-proBNP) was assessed additionally. Results Pulmonary regurgitation (PR), right ventricular (RV) volumes and QRS duration increased during 5-year follow-up (RV end-diastolic volume (EDV) 130 ± 30 ml/m2 to 138 ± 34 ml/m2; QRS 132 ± 27 msec to 139 ± 27 msec); peak VO2 decreased (96 ± 19% to 91 ± 17%). RV ejection fraction, RV effective stroke volume (eff.SV), and NT-proBNP levels remained unchanged. The slope of RVEDV increase was 1.6 ± 3.0 ml/m 2/year, and depended on RVeff.SV, not on RVEDV, at baseline. Increase in RVEDV correlated with increase in QRS duration over time (r = 0.28, p = 0.016), and with decrease in RV mass/EDV ratio over time (r = - 0.42, p < 0.001), not with decrease in peak VO2. In subgroup analysis, patients with larger RVs at baseline showed larger increase in PR during follow-up and larger decrease in NYHA class over time. Conclusions In TOF patients with moderate RV dilatation, RVEDV increased by 1.6 ± 3.0 ml/m 2/year, irrespective of RV size at baseline, but depended on RVeff.SV at baseline. Despite limited progression in RV size, unfavourable changes occurred during 5 years follow-up, which suggests there is a need for close follow-up. © 2013 Elsevier Ireland Ltd.

Cite

CITATION STYLE

APA

Luijnenburg, S. E., Helbing, W. A., Moelker, A., Kroft, L. J. M., Groenink, M., Roos-Hesselink, J. W., … Mulder, B. J. M. (2013). 5-year serial follow-up of clinical condition and ventricular function in patients after repair of tetralogy of Fallot. International Journal of Cardiology, 169(6), 439–444. https://doi.org/10.1016/j.ijcard.2013.10.013

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free