Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings

0Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND AND PURPOSE: CSF-venous fistulas (CVFs) associated with spontaneous intracranial hypotension (SIH) may have a transient appearance, relative to contrast arrival, which may influence the diagnostic performance of lateral decubitus CT myelography (CTM). We developed a dynamic CTM protocol using real-time bolus-tracking (dCTM-BT) to improve the temporal resolution and standardize the timing of CTM acquisitions post-intrathecal contrast administration. The purpose of our study was to evaluate the feasibility of the dCTM-BT technique and evaluate its diagnostic yield for CVF detection, stratified by brain MRI SIH findings. MATERIALS AND METHODS: Patients with suspected SIH without extradural fluid collection on spine MRI who underwent dCTMBT were retrospectively reviewed. CT bolus monitoring was performed at the upper thoracic level. Following the visualization of dense intrathecal contrast, at least 3 CTM acquisitions of the spine were obtained and reviewed by 2 neuroradiologists. The Bern SIH score was calculated on the brain MRI. The diagnostic yield for CVF detection was evaluated, stratified by Bern score categories and a receiver operating characteristic (ROC) analysis. RESULTS: Out of 48 patients, 23 (48%) had a CVF on dCTM-BT, located at T1-5 (n = 4), T6-12 (n = 18), L1 (n = 1), with 70% on the right. CVF was identified in 22/22 (100%) of patients who had a high Bern score, 1/7 (14%) of those who had an intermediate score, and 0/19 (0%) of those who had a low score. The area under the ROC curve was 0.99 (95% CI, 0.98-1.00). The optimal cutoff was a Bern score of ≥5 (96% sensitivity, 100% specificity). CONCLUSIONS: dCTM-BT is feasible and has excellent diagnostic performance for CVF identification/localization. The Bern score is strongly associated with CVF detection and may help inform who will benefit from dCTM-BT.

Cite

CITATION STYLE

APA

Huynh, T. J., Parizadeh, D., Ahmed, A. K., Gandia, C. T., Davison, H. C., Murray, J. V., … Fermo, O. (2024). Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings. American Journal of Neuroradiology, 45(1), 105–112. https://doi.org/10.3174/ajnr.A8082

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free