Risk factors associated with hemodialysis central venous catheter malfunction; a retrospective analysis of a randomized controlled trial

11Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: We previously reported a reduction in central venous catheter (CVC) malfunction when using once-weekly recombinant tissue-plasminogen activator (rt-PA) as a locking solution, compared with thrice-weekly heparin. Objectives: To identify risk factors for CVC malfunction to inform a targeted strategy for rt-PA use. Design: Retrospective analysis. Setting: Canadian hemodialysis (HD) units. Patients: Adults with newly placed tunnelled upper venous system CVCs randomized to a locking solution of rt-PA (1 mg/mL) mid-week and heparin (5000 u/ml) on the other HD sessions, or thrice-weekly heparin (5000 u/ml). Measurements: CVC malfunction (the primary outcome) was defined as: peak blood flow less than 200 mL/min for thirty minutes during a HD session; mean blood flow less than 250 mL/min for two consecutive HD sessions; inability to initiate HD. Methods: Cox regression was used to determine the association between patient demographics, HD session CVC-related variables and the outcome of CVC malfunction. Results: Patient age (62.4 vs 65.4 yr), proportion female sex (35.6 vs 48.4%), and proportion with first catheter ever (60.7 vs 61.3%) were similar between patients with and without CVC malfunction. After multivariate analysis, risk factors for CVC malfunction were mean blood processed < 65 L when compared with ≥ 85 L in the prior 6 HD sessions (HR 4.36; 95% CI, 1.59 to 11.95), and mean blood flow < 300 mL/min, or 300 - 324 mL/min in the prior 6 HD sessions (HR 7.65; 95% CI, 2.78 to 21.01, and HR 5.52; 95% CI, 2.00 to 15.23, respectively) when compared to ≥ 350 mL/min. Limitations: This pre-specified post-hoc analysis used a definition of CVC malfunction that included blood flow, which may result in an overestimate of the effect size. Generalizability of results to HD units where trisodium citrate locking solution is used may also be limited. Conclusions: HD session characteristics including mean blood processed and mean blood flow were associated with CVC malfunction, while patient characteristics were not. Whether targeting these patients at greater risk of CVC malfunction with rt-PA as a locking solution improves CVC longevity remains to be determined.

Cite

CITATION STYLE

APA

Ward, D. R., Moist, L. M., MacRae, J. M., Scott-Douglas, N., Zhang, J., Tonelli, M., … Hemmelgarn, B. R. (2014). Risk factors associated with hemodialysis central venous catheter malfunction; a retrospective analysis of a randomized controlled trial. Canadian Journal of Kidney Health and Disease, 1(1), 1–7. https://doi.org/10.1186/2054-3581-1-15

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free