An ultrasensitive fluorescent aptasensor based on truncated aptamer and AGET ATRP for the detection of bisphenol A

6Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Given the gigantic harmfulness of bisphenol A (BPA), a novel and ultrasensitive aptasensor, which employs the truncated BPA aptamer, click chemistry, and activators generated by electron transfer for atom transfer radical polymerization (AGET ATRP), was developed herein for the quantitative determination of BPA. Firstly, hairpin DNAs (hairpins) with a thiol at the 5′ end and an azide group at the 3′ end were conjugated with aminated magnetic beads (MBs) through heterobifunctional cross-linkers. BPA truncated aptamer (ssDNA-A) hybridizes with its complementary single-stranded DNA (ssDNA-B) to form double-stranded DNA. In the presence of BPA, ssDNA-A specifically captures BPA, and then ssDNA-B is released. Subsequently, the ssDNA-B hybridizes with hairpins to expose the azide group near the surface of the MBs. Then, propargyl-2-bromoisobutyrate (PBIB), the initiator of AGET ATRP containing alkynyl group, was conjugated with azide group of hairpins via the Cu(I)-catalyzed azide-alkyne cycloaddition (CuAAC). Consequently, a large number of fluorescein-o-acrylate (FA) were introduced to the MBs through AGET ATRP, resulting in that the fluorescence intensity was increased dramatically. Obviously, the fluorescence intensity was especially sensitive to the change of BPA concentration, and this method can be used in quantitative determination of BPA. Under optimal conditions, a broad liner range from 100 fM to 100 nM and a low limit of detection (LOD) of 6.6 fM were obtained. Moreover, the method exhibits not only excellent specificity for BPA detection over BPA analogues but high anti-interference ability in real water sample detection, indicating that it has huge application prospect in food safety and environment monitoring.

Cite

CITATION STYLE

APA

Guo, Z., Tang, J., Li, M., Liu, Y., Yang, H., & Kong, J. (2019). An ultrasensitive fluorescent aptasensor based on truncated aptamer and AGET ATRP for the detection of bisphenol A. Analytical and Bioanalytical Chemistry, 411(29), 7807–7815. https://doi.org/10.1007/s00216-019-02179-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free