Expiratory time constant for determinations of plateau pressure, respiratory system compliance, and total resistance

44Citations
Citations of this article
100Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: We hypothesized the expiratory time constant (T{hooktop}E) may be used to provide real time determinations of inspiratory plateau pressure (Pplt), respiratory system compliance (Crs), and total resistance (respiratory system resistance plus series resistance of endotracheal tube) (Rtot) of patients with respiratory failure using various modes of ventilatory support.Methods: Adults (n = 92) with acute respiratory failure were categorized into four groups depending on the mode of ventilatory support ordered by attending physicians, i.e., volume controlled-continuous mandatory ventilation (VC-CMV), volume controlled-synchronized intermittent mandatory ventilation (VC-SIMV), volume control plus (VC+), and pressure support ventilation (PSV). Positive end expiratory pressure as ordered was combined with all aforementioned modes. Pplt, determined by the traditional end inspiratory pause (EIP) method, was combined in equations to determine Crs and Rtot. Following that, the T{hooktop}Emethod was employed, T{hooktop}Ewas estimated from point-by-point measurements of exhaled tidal volume and flow rate, it was then combined in equations to determine Pplt, Crs, and Rtot. Both methods were compared using regression analysis.Results: T{hooktop}E, ranging from mean values of 0.54 sec to 0.66 sec, was not significantly different among ventilatory modes. The T{hooktop}Emethod was an excellent predictor of Pplt, Crs, and Rtot for various ventilatory modes; r2values for the relationships of T{hooktop}Eand EIP methods ranged from 0.94 to 0.99 for Pplt, 0.90 to 0.99 for Crs, and 0.88 to 0.94 for Rtot (P <0.001). Bias and precision values were negligible.Conclusions: We found the T{hooktop}Emethod was just as good as the EIP method for determining Pplt, Crs, and Rtot for various modes of ventilatory support for patients with acute respiratory failure. It is unclear if the T{hooktop}Emethod can be generalized to patients with chronic obstructive lung disease. T{hooktop}Eis determined during passive deflation of the lungs without the need for changing the ventilatory mode and disrupting a patient's breathing. The T{hooktop}Emethod obviates the need to apply an EIP, allows for continuous and automatic surveillance of inspiratory Pplt so it can be maintained ≤ 30 cm H2O for lung protection and patient safety, and permits real time assessments of pulmonary mechanics. © 2013 Al Rawas et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Al-Rawas, N., Banner, M. J., Euliano, N. R., Tams, C. G., Brown, J., Martin, A. D., & Gabrielli, A. (2013). Expiratory time constant for determinations of plateau pressure, respiratory system compliance, and total resistance. Critical Care, 17(1). https://doi.org/10.1186/cc12500

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free