Compensation of the Skin Effect in Low-Frequency Potential Drop Measurements

24Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Potential drop measurements are routinely used in the non-destructive evaluation of component integrity. Potential drop measurements use either direct current (DC) or alternating current (AC), the latter will have superior noise performance due to the ability to perform phase sensitive detection and the reduction of flicker noise. AC measurements are however subject to the skin effect where the current is electromagnetically constricted to the surface of the component. Unfortunately, the skin effect is a function of magnetic permeability, which in ferromagnetic materials is sensitive to a number of parameters including stress and temperature, and consequently in-situ impedance measurements are likely to be unstable. It has been proposed that quasi-DC measurements, which benefit from superior noise performance, but also tend to the skin-effect independent DC measurement, be adopted for in-situ creep measurements for power station components. Unfortunately, the quasi-DC measurement will only tend to the DC distribution and therefore some remnant sensitivity to the skin effect will remain. This paper will present a correction for situations where the remnant sensitivity to the skin effect is not adequately suppressed by using sufficiently low frequency; the application of particular interest being the in-situ monitoring of the creep strain of power station components. The correction uses the measured phase angle to approximate the influence of the skin effect and allow recovery of the DC-asymptotic value of the resistance. The basis of the correction, that potential drop measurements are minimum phase is presented and illustrated on two cases; the creep strain sensor of practical interest and a conducting rod as another common case to illustrate generality. The correction is demonstrated experimentally on a component where the skin effect is manipulated by application of a range of elastic stresses.

References Powered by Scopus

Electrical conductivity measurement of metal plates using broadband eddy-current and four-point methods

123Citations
N/AReaders
Get full text

The use of DCPD method for measurement of growth of cracks in large components at normal and elevated temperatures

73Citations
N/AReaders
Get full text

Frequency- and time-domain analysis of skin effects

72Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Induction Heating: An Enabling Technology for the Heat Management in Catalytic Processes

164Citations
N/AReaders
Get full text

Alternating current electrospinning: The impacts of various high-voltage signal shapes and frequencies on the spinnability and productivity of polycaprolactone nanofibers

71Citations
N/AReaders
Get full text

Lightweight, few-layer graphene composites with improved electro-thermal properties as efficient heating devices for de-icing applications

42Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Corcoran, J., & Nagy, P. B. (2016). Compensation of the Skin Effect in Low-Frequency Potential Drop Measurements. Journal of Nondestructive Evaluation, 35(4). https://doi.org/10.1007/s10921-016-0374-4