Evaluation of di-potassium and tri-potassium EDTA evacuated tubes for routine haematological testing

19Citations
Citations of this article
43Readers
Mendeley users who have this article in their library.

Abstract

Background: The influence of blood collection devices on laboratory tests is often overlooked. We have discussed here how blood collection materials and devices can alter haematological test results, with an emphasis on blood collection tube (BCT) additives. We have compared K2 & K3-EDTA vacuum tubes of same manufacturer IMPROVACUTER ® for CBC analysis. Methods: Blood was collected in both tubes simultaneously. Samples were analysed immediately after collection (<15 minutes) and after 4 hours by MEK−6318J/K Haematology Analyzer. Paired student's t-test was applied for statistical analysis. Significant differences among results and biases were compared with current quality specifications. Results: Significant differences were found in Neutrophyls (GR) and mean platelets volume (MPV) when compared. K2-EDTA vs K3-EDTA(1st time) after< 15 minutes of sample collection, for Monocytes counts (MO), MCV, MPV, and RDW when comparing K2-EDTA (first time) vs K2-EDTA(second time, after 4 hours); and for Monocytes counts (MO), MCV, MPV, PCT, and RDW when comparing K3-EDTA(1st time) vs K3-EDTA(2nd time) in order to check the stability and reproducibility of vacutainers. Conclusions: This study assesses the use of K2& K3-EDTA vacuum tubes whether or not they represent a bias in haematological testing (CBC). The use of K2-EDTA and K3-EDTA vacuum tubes represent a clinically relevant source of variation for MCV, MPV, RDW, and PCT.

References Powered by Scopus

Current databases on biological variation: Pros, cons and progress

989Citations
N/AReaders
Get full text

Mean platelet volume is an independent risk factor for myocardial infarction but not for coronary artery disease

416Citations
N/AReaders
Get full text

Platelet size deviation width, platelet large cell ratio, and mean platelet volume have sufficient sensitivity and specificity in the diagnosis of immune thrombocytopenia

206Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Liquid biopsies

129Citations
N/AReaders
Get full text

Selective electrochemical sensing of hemoglobin from blood of β-thalassemia major patients by tellurium nanowires-graphene oxide modified electrode

19Citations
N/AReaders
Get full text

Correction of spurious low platelet counts by optical fluorescence platelet counting of BC-6800 hematology analyzer in EDTA-dependent pseudo thrombocytopenia patients

12Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mehmood, R., Muhammed, R. K., Hussain, S., & Sana, A. (2018). Evaluation of di-potassium and tri-potassium EDTA evacuated tubes for routine haematological testing. Journal of Clinical Laboratory Analysis, 32(1). https://doi.org/10.1002/jcla.22188

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

58%

Lecturer / Post doc 2

17%

Researcher 2

17%

Professor / Associate Prof. 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

31%

Biochemistry, Genetics and Molecular Bi... 4

31%

Pharmacology, Toxicology and Pharmaceut... 3

23%

Agricultural and Biological Sciences 2

15%

Save time finding and organizing research with Mendeley

Sign up for free