1D/3D Coupling Calculation Analysis on Bus Cooling System

  • Shen K
  • Li F
  • Ni J
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Compared with front engine vehicle, the windward side's flow field in cooling model of rear engine bus is complicated and it can't be calculated by means of 1D model. For this problem, this paper has used Star-CCM to build a 3D simulation model of cooling system, engine compartment and complete vehicle. Then, it had a 1D/3D coupling calculation on cooling system with Kuli software. It could be helpful in the optimization design of the flow field of rear engine compartment and optimization match of cooling system.

Cite

CITATION STYLE

APA

Shen, K., Li, F., & Ni, J. (2014). 1D/3D Coupling Calculation Analysis on Bus Cooling System. Energy and Power Engineering, 06(14), 550–556. https://doi.org/10.4236/epe.2014.614048