Geometric calibration of thermographic cameras

45Citations
Citations of this article
89Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This chapter presents an overview of thermal imaging sensors for photogrammetric close-range applications. In particular, it presents results of the geometric calibration of thermographic cameras as they are used for building inspection and material testing. Geometric calibration becomes evident for all precise geometric image operations, e.g. mosaicking of two or more images or photogrammetric 3D modelling with thermal imagery. Two different test fields have been designed providing point targets that are visible in the thermal spectral band of the cameras. Five different cameras have been investigated. Four of them have solid state sensors with pixel sizes between 25 and 40 µm (i.e. size of single sensor element on the chip). One camera is working in scanning mode. The lenses for thermographic cameras are made of Germanium, which is, in contrast to glass, transparent to thermal radiation. Conventional imaging configurations (typically 20 images) have been used for camera calibration. Standard parameters for principal distance, principal point, radial distortion, decentring distortion, affinity and shear have been introduced into the self-calibrating bundle adjustment. All measured points are introduced as weighted control points. Image coordinates have been measured either in the professional software package AICON 3D Studio (ellipse operators), or in the software system Stereomess (least-squares template matching), developed by the Institute for Applied Photogrammetry and Geoinformatics of the Jade University of Applied Sciences Oldenburg. The calibration results differ significantly from camera to camera. All lenses show relatively large decentring distortion and deviations from orthogonality of the image coordinate axes. Using a plane test field with heated lamps, the average image precision is 0.3 pixel while a 3D test field with circular reflecting targets results in imaging errors of 0.05 pixel.

Cite

CITATION STYLE

APA

Luhmann, T., Piechel, J., & Roelfs, T. (2013). Geometric calibration of thermographic cameras. In Remote Sensing and Digital Image Processing (Vol. 17, pp. 27–42). Springer International Publishing. https://doi.org/10.1007/978-94-007-6639-6_2

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free