This study aims to investigate the heat and thermal insulation mechanisms of aerogel heat-insulating reflective coatings. Two working conditions, the hot box method and the open environment at the hot end, were simulated using a gypsum board as the substrate. We conducted thermal tests on blank panels, composite panels with aerogel heat-insulating reflective coatings, and XPS-insulated composite panels for two operating conditions. And the thermal insulation power calculation was carried out for the reflective and barrier materials. The test results show that the air temperature differences between the hot and cold ends of the blank, aerogel coating, and XPS boards under the hot box method were 28.8 °C, 38.2 °C, and 55.2 °C, respectively, and that the air temperature differences between the cold ends of the coating and XPS panels under the natural environment heating condition were 24.2 °C and 24 °C, respectively. Theoretical calculations show that the aerogel heat-insulating reflective coatings produce a net radiative cooling power of 145.9 W/m² when the surface of the specimen is at the same temperature as the ambient temperature. The heat flux powers of the aerogel coating board and XPS panel were 9.55 W/m² and 1.65 W/m² when the temperature difference between the two surfaces on both sides of the specimen was 10 °C, respectively.
CITATION STYLE
Liu, Y. L., Yang, D. G., Wang, D. H., & Liu, X. (2023). Research on Thermal and Heat Insulation Properties of Aerogel Heat-Insulating Reflective Coatings. Applied Sciences (Switzerland), 13(17). https://doi.org/10.3390/app13179700
Mendeley helps you to discover research relevant for your work.