An Analysis of 2019 FDA Adverse Events for Two Insulin Pumps and Two Continuous Glucose Monitors

7Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

US Food and Drug Administration adverse event data for 2019 were analyzed for two insulin pumps and two continuous glucose monitors (CGMs). The analyses were selective—they were guided by the text described in the adverse events. They included (1) percent using auto mode for the Medtronic 670G pump, (2) distributions of hyper and hypo glucose values for Medtronic and Tandem pumps, (3) a Parkes error grid for Dexcom CGM vs glucose meter when the complaint was inaccuracy, and (4) the most frequent events for Abbott Freestyle. We found that for the 670G pump, there were more hypo events when auto mode was on than when auto mode was off. With Dexcom CGMs, users complained about inaccurate result when most results were in the B zone. With the Abbott Freestyle, the most frequent adverse event was an allergic skin reaction.

References Powered by Scopus

A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose

503Citations
N/AReaders
Get full text

One year clinical experience of the first commercial hybrid closed-loop system

183Citations
N/AReaders
Get full text

Real world hybrid closed-loop discontinuation: Predictors and perceptions of youth discontinuing the 670G system in the first 6 months

129Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Continuous Glucose Deviation Interval and Variability Analysis (CG-DIVA): A Novel Approach for the Statistical Accuracy Assessment of Continuous Glucose Monitoring Systems

12Citations
N/AReaders
Get full text

Insulin Pump-Associated Adverse Events: A Qualitative Descriptive Study of Clinical Consequences and Potential Root Causes

6Citations
N/AReaders
Get full text

Adverse Event Causes From 2022 for Four Continuous Glucose Monitors

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Krouwer, J. S. (2022, January 1). An Analysis of 2019 FDA Adverse Events for Two Insulin Pumps and Two Continuous Glucose Monitors. Journal of Diabetes Science and Technology. SAGE Publications Inc. https://doi.org/10.1177/1932296820951872

Readers' Seniority

Tooltip

Researcher 2

67%

Professor / Associate Prof. 1

33%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

40%

Materials Science 1

20%

Pharmacology, Toxicology and Pharmaceut... 1

20%

Engineering 1

20%