Sampling of exhaled nitric oxide in children: End-expiratory plateau, balloon and tidal breathing methods compared

47Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

The aim of this study was to compare exhaled nitric oxide concentrations obtained during controlled slow exhalation, presently considered as the method of choice, with two sampling methods that are easily performed by children: blowing air into a balloon and tidal breathing through a mouthpiece. One hundred and one well controlled, stable allergic asthmatic children (median age 11.7 yrs) performed the following tasks in duplicate: 1) exhalation from total lung capacity through a mouthpiece against a resistor with a standardized flow rate of 20% of the subject's vital capacity per second, using a biofeedback system; 2) a single deep exhalation into an NO- impermeable mylar balloon; and 3) tidal breathing through a low resistance mouthpiece over 2 min. NO was measured using a chemiluminescence analyser. Twenty-nine children (29%) were not able to perform a constant-flow exhalation of at least 3 s. All children performed the balloon and tidal breathing methods without difficulty. NO concentrations (means±SEM were 5.3±0.2 parts per billion (ppb) at the end-expiratory plateau, 5.2±0.3 ppb in balloons (intraclass correlation coefficient (r(i))=0.73) and 8.0±0.4 ppb during tidal breathing (p<0.001, r(i)=0.53 compared to plateau values). Mean values of NO during tidal breathing increased significantly with time, suggesting increasing contamination with nasal air. It was concluded that, in asthmatic children, the end-expiratory plateau concentration of nitric oxide during exhalation at 20% of the vital capacity per second is similar to the values obtained with the balloon method, with satisfactory agreement, but differs from values obtained during tidal breathing. The balloon method is cheap, simple and offers the interesting possibility to study exhaled nitric oxide in young children independently of the presence of a nitric oxide analyser.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42164Citations
N/AReaders
Get full text

Increased nitric oxide in exhaled air of asthmatic patients

1355Citations
N/AReaders
Get full text

Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans

859Citations
N/AReaders
Get full text

Cited by Powered by Scopus

ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005

0
3089Citations
N/AReaders
Get full text

Exhaled nitric oxide measurements: Clinical application and interpretation

444Citations
N/AReaders
Get full text

Measurement of exhaled nitric oxide in children, 2001

321Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Jöbsis, Q., Schellekens, S. L., Kroesbergen, A., Hop, W. C. J., & De Jongste, J. C. (1999). Sampling of exhaled nitric oxide in children: End-expiratory plateau, balloon and tidal breathing methods compared. European Respiratory Journal, 13(6), 1406–1410. https://doi.org/10.1034/j.1399-3003.1999.13f29.x

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

67%

Professor / Associate Prof. 1

17%

Researcher 1

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

67%

Nursing and Health Professions 1

17%

Social Sciences 1

17%

Save time finding and organizing research with Mendeley

Sign up for free