Abstract

Background: Gait disturbance is a major contributor to clinical disability in multiple sclerosis (MS). A sensor was developed to assess walking speed at home for people with MS using infrared technology in real-time without the use of wearables. Objective: To develop continuous in-home outcome measures to assess gait in adults with MS. Methods: Movement measurements were collected continuously for 8 months from six people with MS. Average walking speed and peak walking speed were calculated from movement data, then analyzed for variability over time, by room (location), and over the course of the day. In-home continuous gait outcomes and variability were correlated with standard in-clinic gait outcomes. Results: Measured in-home average walking speed of participants ranged from 0.33 m/s to 0.96 m/s and peak walking speed ranged from 0.89 m/s to 1.51 m/s. Mean total within-participant coefficient of variation for daily average walking speed and peak walking speed were 10.75% and 10.93%, respectively. Average walking speed demonstrated a moderately strong correlation with baseline Timed 25-Foot Walk (rs = 0.714, P ¼ 0.111). Conclusion: New non-wearable technology provides reliable and continuous in-home assessment of walking speed.

References Powered by Scopus

Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)

13545Citations
N/AReaders
Get full text

Relapses and progression of disability in multiple sclerosis

1129Citations
N/AReaders
Get full text

Measuring the impact of MS on walking ability: The 12-item MS Walking Scale (MSWS-12)

683Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Beyond center-based testing: Understanding and improving functioning with wearable technology in MS

29Citations
N/AReaders
Get full text

Objective sensor-based gait measures reflect motor impairment in multiple sclerosis patients: Reliability and clinical validation of a wearable sensor device

23Citations
N/AReaders
Get full text

Novel technology for mobility and balance tracking in patients with multiple sclerosis: a systematic review

17Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Smith, V. M. J., Varsanik, J. S., Walker, R. A., Russo, A. W., Patel, K. R., Gabel, W., … Klawiter, E. C. (2018). Movement measurements at home for multiple sclerosis: Walking speed measured by a novel ambient measurement system. Multiple Sclerosis Journal - Experimental, Translational and Clinical, 4(1). https://doi.org/10.1177/2055217317753465

Readers over time

‘18‘19‘20‘21‘22‘23‘24‘2506121824

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 19

79%

Researcher 4

17%

Professor / Associate Prof. 1

4%

Readers' Discipline

Tooltip

Medicine and Dentistry 7

37%

Neuroscience 6

32%

Sports and Recreations 4

21%

Nursing and Health Professions 2

11%

Save time finding and organizing research with Mendeley

Sign up for free
0