We have prospectively studied the outcome of infections associated with implants which were retained and treated using a standardised antimicrobial protocol. Over a period of four years, we studied 24 consecutive patients who had symptoms of infection for less than one year, a stable implant, no sinus tract and a known pathogen which was susceptible to recommended antimicrobial agents. The infections involved hip prostheses (14), knee prostheses (5), an internal fixation device (4), and an ankle prosthesis (1). Twenty patients had a successful outcome at a median follow-up of 3.7 years (1.8 to 4.7); four had failure of the implant after a median follow-up of 1.2 years (0.3 to 2.5). The probability of survival without failure of treatment was 96% at one year (95% confidence interval (Cl) 88 to 100), 92% at two years (95% Cl 80 to 100) and 86% at three years (95% Cl 72 to 100). Patients with a short-term infection but with a stable implant, no sinus tract and a known pathogen may be successfully treated by retention of the implant and the use of a standardised regimen of antimicrobial treatment. ©2005 British Editorial Society of Bone and Joint Surgery.
CITATION STYLE
Trebse, R., Pisot, V., & Trampuz, A. (2005). Treatment of infected retained implants. Journal of Bone and Joint Surgery - Series B, 87(2), 249–256. https://doi.org/10.1302/0301-620X.87B2.15618