A novel pre-column derivatization reversed-phase high-performance liquid chromatography with fluorescence detection is described for the determination of bupropion in pharmaceutical preparation, human plasma and human urine using mexiletine as internal standard. The proposed method is based on the reaction of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with bupropion to produce a fluorescent derivative. The derivative formed is monitored on a C18 (150 mm × 4.6 mm i.d., 5 μm) column using a mobile phase consisting of methanolwater 75:25 (v/v), at a flow-rate of 1.2 mL/min and detected fluorimetrically at λex 458 and λem 533 nm. The assay was linear over the concentration ranges of 5500 and 10500 ng/mL for plasma and urine, respectively. The limits of detection and quantification were calculated to be 0.24 and 0.72 ng/mL for plasma and urine, respectively (inter-day results). The recoveries obtained for plasma and urine were 97.12 ± 0.45 and 96.00 ± 0.45, respectively. The method presents good performance in terms of precision, accuracy, specificity, linearity, detection and quantification limits and robustness. The proposed method is applied to determine bupropion in commercially available tablets. The results were compared with an ultraviolet spectrophotometry method using t-and F-tests. © 2012 The Author.
CITATION STYLE
Ulu, S. T., & Tuncel, M. (2012). Determination of bupropion using liquid chromatography with fluorescence detection in pharmaceutical preparations, human plasma and human urine. Journal of Chromatographic Science, 50(5), 433–439. https://doi.org/10.1093/chromsci/bms020