Quantitative myocardial perfusion byO-15-water PET: Individualized vs. standardized vascular territories

24Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims Reporting of quantitative myocardial blood flow(MBF) is typically performed in standard coronary territories. However, coronary anatomy and myocardial vascular territories vary among individuals, and a coronary artery may erroneously be deemed stenosed or not if territorial demarcation is incorrect. So far, the diagnostic consequences of calculating individually vs. standardly assessed MBF values have not been reported. We examined whether individual reassignment of vascular territories would improve the diagnostic accuracy of MBF with regard to the detection of significant coronary artery disease (CAD). Methods and results Forty-four patients with suspected CAD were included prospectively and underwent coronary CT-angiography and quantitative MBF assessment with O-15-water PET followed by invasive, quantitative coronary angiography, which served as reference. MBF was calculated in the vascular territories during adenosine stress according to a standardized 17-segment American Heart Association model and an individualized model, using CT-angiography to adjust the coronary territories to their feeding vessels. Individually defined territories deviated from standard territories in 52% of patients. However, MBF in the three coronary territories defined by standard and individualized models did not differ significantly, except in one patient, in whom the MBF of an individualized coronary territory deviated sufficiently as to change the test from a false positive to a true negative result in this particular territory. Conclusion Disparity between standardized and individualized vascular territories was present in half of the patients, but had little clinical impact. Still, caution should be taken not always to rely on standard territories, as this may at times cause misinterpretation.

Cite

CITATION STYLE

APA

Thomassen, A., Petersen, H., Johansen, A., Braad, P. E., Diederichsen, A. C. P., Mickley, H., … Høilund-Carlsen, P. F. (2015). Quantitative myocardial perfusion byO-15-water PET: Individualized vs. standardized vascular territories. European Heart Journal Cardiovascular Imaging, 16(9), 970–976. https://doi.org/10.1093/ehjci/jev111

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free