Background: Clinical diagnoses were correlated with results of a Co(II)-albumin binding assay in 167 patients treated at an emergency department of a health maintenance organization. Methods: Patients were evaluated as being nonischemic or potentially ischemic through standard coronary disease indicators [creatine kinase (CK), CK-MB, cardiac troponin I, and electrocardiographic findings] and were tested by a Co(II)-albumin binding assay. Samples were tested anonymously, and the study was double-blinded. The sensitivity and specificity of this assay for the detection of ischemia were evaluated by ROC curve analysis. Known Co(II) binding sites on albumin were analyzed by N-terminal amino acid sequencing. Results: The mean absorbance units (ABSU) ± 2 SD for non-myocardial ischemic and myocardial ischemic individuals measured at 470 nm were 0.43 ± 0.10 and 0.63 ± 0.25, respectively (P <0.0001). The area under the ROC curve was 0.95 [95% confidence interval (CI), 0.92-0.99], and at a cutoff value of 0.50 ABSU, sensitivity and specificity were 88% (78-94%) and 94% (86-98%), respectively, suggesting a high distinction between the two groups. When we compared non-acute myocardial infarction (AMI) and AMI ischemic individuals, the area under the ROC curve was 0.66 (95% CI, 0.53-0.79) and was considered a poor discriminator between these two groups. N-Terminal amino acid sequencing data for purified albumin showed normal amino acid residues for six of seven high-ABSU (≥0.70) individuals and one nonischemic individual tested. However, only one individual with a high ABSU (0.80) had two missing amino acid residues (DA) from the N-terminal region. Clinical diagnosis for this patient did not reveal an ischemic event. Conclusions: The Co(II)-albumin binding test may serve as a useful diagnostic tool in emergency facilities for the assessment of myocardial ischemia. High and low ABSU were associated with myocardial ischemic individuals and non-myocardial ischemic individuals, respectively. However, the Co(II)-albumin binding was a poor discriminator between ischemic individuals with and without MI. © 2003 American Association for Clinical Chemistry.
CITATION STYLE
Bhagavan, N. V., Lai, E. M., Rios, P. A., Yang, J., Ortega-Lopez, A. M., Shinoda, H., … Ha, C. E. (2003). Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction. Clinical Chemistry, 49(4), 581–585. https://doi.org/10.1373/49.4.581
Mendeley helps you to discover research relevant for your work.