Transitioning the total hip arthroplasty technique from posterior approach in lateral position to direct anterior approach in supine position—risk factors for acetabular malpositioning and the learning curve

17Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Cup positioning is important for optimum hip stability, avoiding component impingement and decreasing both bearing surface wear and revision rate. Transitioning from posterior approach in a lateral position to direct anterior approach (DAA) in a supine presents unique challenges for surgeons. The aim of this study was to examine the learning curve when using standard instrumentation that was not specific to DAA. Methods: A consecutive retrospective series of 537 total hip arthroplasty by DAA from May 2013 to December 2017. Cup positioning was analysed on radiographs and classified whether inside or outside two safe zones (inclination 30–50° and anteversion 10–30°). The demographic data (age, BMI, gender, neck shaft angle (NSA)), surgeon’s dominant side and experience were assessed as risk factors. Results: Eighty per cent of cups (n = 426) were in the combined safe zones. Eighty-eight per cent (n = 470) were in appropriate anteversion and 87% (n = 463) abduction. Two factors that were significant were identified: Cups of left hips operated by right-handed surgeons were more anteverted (OR = 4.06) and more vertical (OR = 2.23); females had a higher anteversion of the cup (OR = 2.42). Obesity, age and NSA were not risk factors for cup malposition. There was a spike of cups too horizontal at the beginning of the experience (OR = 3.86), and no learning curve was observed in the other orientations. Conclusion: With our DAA technique using standard instrumentation, there were no risk factors linked to the patient identified for cup malposition. DAA-specific instrumentation is not required to achieve optimum positioning of the cup. Surgeon has to be aware of an excess of abduction at the beginning of his experience and an excess of anteversion and adduction when performing THA on the opposite side of his dominant hand.

References Powered by Scopus

Dislocations after total hip-replacement arthroplasties

2413Citations
N/AReaders
Get full text

Single-incision anterior approach for total hip arthroplasty on an orthopaedic table

561Citations
N/AReaders
Get full text

The john charnley award: Risk factors for cup malpositioning: Quality improvement through a joint registry at a tertiary hospital

488Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The learning curve for the direct anterior total hip arthroplasty: a systematic review

59Citations
N/AReaders
Get full text

Image-based robotic-assisted total hip arthroplasty through direct anterior approach allows a better orientation of the acetabular cup and a better restitution of the centre of rotation than a conventional procedure

20Citations
N/AReaders
Get full text

Greater trochanter fractures in the direct anterior approach: evolution during learning curve, risk factors and consequences

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Foissey, C., Batailler, C., Fary, C., Luceri, F., Servien, E., & Lustig, S. (2020). Transitioning the total hip arthroplasty technique from posterior approach in lateral position to direct anterior approach in supine position—risk factors for acetabular malpositioning and the learning curve. International Orthopaedics, 44(9), 1669–1676. https://doi.org/10.1007/s00264-020-04583-0

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

67%

Researcher 2

22%

Lecturer / Post doc 1

11%

Readers' Discipline

Tooltip

Medicine and Dentistry 7

70%

Sports and Recreations 1

10%

Engineering 1

10%

Veterinary Science and Veterinary Medic... 1

10%

Save time finding and organizing research with Mendeley

Sign up for free