Real-time observation of hemodynamic changes in glomerular aneurysms induced by anti-Thy-1 antibody

19Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Blood flow in the microvasculature plays a pivotal role in determining the outcome of injury and repair in inflamed tissue. Real-time observation of the kidney microvasculature, including the glomerular capillary tufts, is extremely difficult because of the methodological limitations of currently available microscope optics. In the present study, we attempted to analyze hemodynamic events that occurred in vivo during microvascular regeneration following destruction of the glomerular capillary tuft, functionally and quantitatively by the use of a real-time confocal laser-scanning microscope (CLSM) system. Methods. A polyethylene catheter was inserted into the carotid artery to allow blood pressure measurement. Mesangiolytic lesions producing microaneurysms were induced by the injection of anti-Thy-1.1 antibody. On days 3 and 7 after anti-body injection, we examined hemodynamic changes under an intravital microscope equipped with real-time CLSM in combination with a high-speed CCD video camera. To measure vessel diameter and erythrocyte velocity, rats were injected with fluorescein isothiocyanate (FITC)-labeled dextran and FITC-labeled red blood cells (RBCs). Results. On day 3 of the disease, mean arterial blood pressure was 112 ± 5 mm Hg, which was significantly higher than that of normal rat or of rats on day 7 (93 ± 1 and 101 ± 9 mm Hg, respectively). Within mircroaneurysms on day 3, RBC velocity was greatly suppressed. By day 7, RBC velocity, in glomeruli with normal appearances, recovered to about half of the level seen in normal controls (430.6 ± 284.7 μm/sec), while in narrowed glomerular tufts, it was still only 104.6 ± 35.1 μm/sec. Conclusions. The noninvasive procedure, using CLSM in combination with a high-speed video camera, allowed us to examine hemodynamic events quantitatively and to analyze microvascular architecture three dimensionally in the kidney. It is useful for estimating hemodynamic response and vascular regeneration in vivo and may be promising for clinical application.

Cite

CITATION STYLE

APA

Oyanagi-Tanaka, Y., Yao, J., Wada, Y., Morioka, T., Suzuki, Y., Gejyo, F., … Oite, T. (2001). Real-time observation of hemodynamic changes in glomerular aneurysms induced by anti-Thy-1 antibody. Kidney International, 59(1), 252–259. https://doi.org/10.1046/j.1523-1755.2001.00486.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free