Simulation of ultrasonic cleaning and experimental study of the liquid level adjusting method

3Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In this paper the three-dimensional models of ultrasonic cleaning were established in COMSOL Multiphysics and corresponding cleaning effect under different frequencies and liquid levels were simulated. Then the frequencies suitable for remanufactured components were studied and the cleaning effect under different liquid levels were tested by experiment. The experimental results were processed by Matlab and contrasted with simulation results. It shows that the disadvantages caused by the standing wave can be eliminated by adjusting the liquid level.

Cite

CITATION STYLE

APA

Li, F., Ge, S., Qin, S., & Hao, Q. (2013). Simulation of ultrasonic cleaning and experimental study of the liquid level adjusting method. In Re-Engineering Manufacturing for Sustainability - Proceedings of the 20th CIRP International Conference on Life Cycle Engineering (pp. 275–278). Springer Berlin Heidelberg. https://doi.org/10.1007/978-981-4451-48-2_45