Background: Cardiac output (CO) assessment is a corner stone in advanced haemodynamic management, especially in critical ill patients. The present study was conducted to validate cardiac index and cardiac output by NICaS™ with the thermodilution technique using pulmonary artery catheter in post-operative cardiac surgical patients. Materials and Methods: This was a prospective observational clinical study conducted at a tertiary care hospital. 23 adult patients in the age range of 18-65 years who had undergone for elective coronary artery bypass grafting were included in the study. Results: Spearman's correlation coefficient of cardiac index between continuous Thermodilution (cTD) and Non-Invasive Cardiac System (NICaS™) showed a good correlation (r = 0.765, 95% confidence interval 0.70 to 0.82, P < 0.0001). There was a good correlation between cTD and NICaS™ for cardiac output (r = 0.759, 95% confidence interval 0.69 to 0.81, P < 0.0001), Bland-Altman plot for cardiac index between cTD and NICaS™ showed a mean bias of-0.66 ± 0.6919 with limits of agreement being-2.02 to 0.6936. Bland-Altman plot for cardiac output between cTD and NICaS™ showed a mean bias of-1.0386 ± 1.17 with limits of agreement being-3.34 to + 1.26. Percentage error for cardiac index and cardiac output were 64.78% and 64% respectively. Polar plot analysis showed an angular bias of 6.32° with radial limits of agreement being-8.114° to 20.75° for cardiac index and angular bias of 5.6682° with radial limits of agreement being-9.1422° to 20.4784° for cardiac output. Conclusion: NICaS™ demonstrated a good trending ability for both CI and CO. However, NICaS™ derived parameters are not interchangeable with the values derived from continuous thermodilution technique.

References Powered by Scopus

Circulatory shock

1014Citations
N/AReaders
Get full text

A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output

431Citations
N/AReaders
Get full text

Predictors of low cardiac output syndrome after isolated aortic valve surgery

126Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Bioimpedance analysis as a tool for hemodynamic monitoring: Overview, methods and challenges

46Citations
N/AReaders
Get full text

Signal processing techniques applied to impedance cardiography ICG signals–a review

13Citations
N/AReaders
Get full text

Noninvasive Hemodynamic Monitoring in Advanced Heart Failure Patients: New Approach for Target Treatments

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bhavya, G., Nagaraja, P. S., Singh, N. G., Ragavendran, S., Sathish, N., Manjunath, N., … Nayak, V. B. (2020). Comparison of continuous cardiac output monitoring derived from regional impedance cardiography with continuous thermodilution technique in cardiac surgical patients. Annals of Cardiac Anaesthesia, 23(2), 189–192. https://doi.org/10.4103/aca.ACA_1_19

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

50%

Professor / Associate Prof. 3

38%

Researcher 1

13%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

63%

Materials Science 1

13%

Computer Science 1

13%

Social Sciences 1

13%

Save time finding and organizing research with Mendeley

Sign up for free