Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system

5Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Study design: Prospective multi-center study. Objective: The study aimed to evaluate the accuracy of pedicle screw placement using a skin marker-based optical surgical navigation system for minimal invasive thoraco-lumbar-sacral pedicle screw placement. Methods: The study was performed in a hybrid Operating Room with a video camera-based navigation system integrated in the imaging hardware. The patient was tracked with non-invasive skin markers while the instrument tracking was via an on-shaft optical marker pattern. The screw placement accuracy assessment was performed by three independent reviewers, using the Gertzbein grading. The screw placement time as well as the staff and patient radiation doses was also measured. Results: In total, 211 screws in 39 patients were analyzed for screw placement accuracy. Of these 32.7% were in the thoracic region, 59.7% were in the lumbar region, and 7.6% were in the sacral region. An overall accuracy of 98.1% was achieved. No screws were deemed severely misplaced (Gertzbein grading 3). The average time for screw placement was 6 min and 25 secs (± 3 min 33 secs). The average operator radiation dose per subject was 40.3 µSv. The mean patient effective dose (ED) was 11.94 mSv. Conclusion: Skin marker-based ON can be used to achieve very accurate thoracolumbarsacral pedicle screw placements.

References Powered by Scopus

Accuracy of pedicular screw placement in vivo

1181Citations
N/AReaders
Get full text

Statistical Methods in Diagnostic Medicine

704Citations
N/AReaders
Get full text

Assessing obesity: Classification and epidemiology

418Citations
N/AReaders
Get full text

Cited by Powered by Scopus

AI-based automated detection and stability analysis of traumatic vertebral body fractures on computed tomography

11Citations
N/AReaders
Get full text

Fatty Degeneration of the Autochthonous Muscles Is Significantly Associated with Incidental Non-Traumatic Vertebral Body Fractures of the Lower Thoracic Spine in Elderly Patients

5Citations
N/AReaders
Get full text

Task-based image quality assessment of an intraoperative CBCT for spine surgery compared with conventional CT

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Pietro, S., Chatterjea, A., Inge, J., Tim, K., Matthias, W., Sebastian, L., … Andreas, S. (2022). Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system. European Spine Journal, 31(11), 3098–3108. https://doi.org/10.1007/s00586-022-07387-5

Readers over time

‘22‘23‘2400.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

50%

Researcher 2

50%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

67%

Engineering 1

33%

Save time finding and organizing research with Mendeley

Sign up for free
0