In this study, statistical analysis was performed to investigate the influence of operational parameters based on experimental results. The research aimed to know whether a long-term discontinuous module vibration operation is possible without adversely affecting filtration efficiency. Polymer membranes were compared by surface characteristics with contact angle measurements and selected for further membrane filtration experiments for dairy wastewater treatment. The effect of the main operational parameters, membrane module vibration amplitude (Avibr.) and transmembrane pressure (TMP), was investigated using a vibratory shear enhanced processing (VSEP) module with ultrafiltration (UF) and nanofiltration (NF) membranes. Components of the permeates, including chemical oxygen demand (COD), were measured, and membrane rejections were calculated to compare with threshold limit values. The results suggest that proper combination of Avibr. and TMP could mitigate membrane fouling. However, discontinuous module vibration resulted in more clogged membrane with lower fluxes, but slightly higher rejections. We conclude that investigating the significance of operational parameters is necessary for a wider, more energy and environment-friendly application in wastewater treatment.
CITATION STYLE
Szerencsés, S. G., Beszédes, S., László, Z., Veréb, G., Szalay, D., Hovorkáné Horváth, Z., … Kertész, S. (2021). Assessment of vibration amplitude and transmembrane pressure on vibratory shear enhanced membrane filtration for treating dairy wastewater. Acta Alimentaria, 50(1), 42–53. https://doi.org/10.1556/066.2020.00123