Assessment of a model based optimization engine for volumetric modulated arc therapy for patients with advanced hepatocellular cancer

104Citations
Citations of this article
72Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND: To evaluate in-silico the performance of a model-based optimization process for volumetric modulated arc therapy (RapidArc) applied to hepatocellular cancer treatments. PATIENTS AND METHODS: 45 clinically accepted RA plans were selected to train a knowledge-based engine for the prediction of individualized dose-volume constraints. The model was validated on the same plans used for training (closed-loop) and on a set of other 25 plans not used for the training (open-loop). Dose prescription, target size, localization in the liver and arc configuration were highly variable in both sets to appraise the power of generalization of the engine. Quantitative dose volume histogram analysis was performed as well as a pass-fail analysis against a set of 8 clinical dose-volume objectives to appraise the quality of the new plans. RESULTS: Qualitative and quantitative equivalence was observed between the clinical and the test plans. The use of model-based optimization lead to a net improvement in the pass-rate of the clinical objectives compared to the plans originally optimized with standard methods (this pass-rate is the frequency of cases where the objectives are respected vs. the cases where constraints are not fulfilled). The increase in the pass-rate resulted of 2.0%, 0.9% and 0.5% in a closed-loop and two different open-loop validation experiments. CONCLUSIONS: A knowledge-based engine for the optimization of RapidArc plans was tested and lead to clinically acceptable plans in the case of hepatocellular cancer radiotherapy. More studies are needed before a broad clinical use.

Cited by Powered by Scopus

Overview of artificial intelligence-based applications in radiotherapy: Recommendations for implementation and quality assurance

227Citations
N/AReaders
Get full text

Automation in intensity modulated radiotherapy treatment planning-a review of recent innovations

200Citations
N/AReaders
Get full text

Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches

182Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Fogliata, A., Wang, P. M., Belosi, F., Clivio, A., Nicolini, G., Vanetti, E., & Cozzi, L. (2014). Assessment of a model based optimization engine for volumetric modulated arc therapy for patients with advanced hepatocellular cancer. Radiation Oncology (London, England), 9, 236. https://doi.org/10.1186/s13014-014-0236-0

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 34

74%

Professor / Associate Prof. 7

15%

Researcher 4

9%

Lecturer / Post doc 1

2%

Readers' Discipline

Tooltip

Physics and Astronomy 21

48%

Medicine and Dentistry 12

27%

Engineering 7

16%

Nursing and Health Professions 4

9%

Save time finding and organizing research with Mendeley

Sign up for free