Long-term observation of graft thickness and shape in Descemet stripping and automated endothelial keratoplasty

1Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To evaluate the thickness and shape of the posterior lamellar graft in Descemet stripping and automated endothelial keratoplasty after long-term observation. Methods: All patients who underwent Descemet stripping and automated endothelial keratoplasty including simple and triple Descemet stripping and automated endothelial keratoplasty between August 2009 and May 2014 were enrolled in this retrospective study. To assess postoperative thickness and shape of the Descemet stripping and automated endothelial keratoplasty graft, images of the graft taken at the center (C), mid-periphery at 4 mm optical zone (P1), and periphery at 6 mm optical zone (P2) at 1, 2, and 3 years postoperatively were obtained using anterior segment optical coherence tomography. Results: C:P1 was 0.96, 0.96, and 0.95 at 1, 2, and 3 years postoperatively, respectively. C:P2 was 0.85, 0.84, and 0.83 at 1, 2, and 3 years postoperatively, respectively. There was a greater thinning of the central graft thickness compared with the peripheral graft thickness. The shapes of the posterior lamellar graft were variable, such as concave, asymmetrical, planar, irregular, and convex meniscus shapes. The most common shape was asymmetrical shape at 1 year postoperatively and concave at 2 and 3 years postoperatively. The most common shape of the posterior lamellar grafts was asymmetrical shape (38.18%) at 1 year postoperatively, followed by concave (34.54%), planar (20.00%), irregular (5.45%), and convex (1.81%) shapes. The most common shape was concave shape (44.44% and 57.14% for 2 and 3 years postoperatively, respectively), followed by asymmetrical (27.77% and 17.85%, respectively), planar (16.66% and 17.85%, respectively), and irregular (11.11% and 7.14%, respectively) shapes. Conclusion: In our study, concave meniscus was not the only observed shape of the graft. The shape and thickness of the graft did not stabilize even 3 years postoperatively in some patients. These findings should be taken into consideration in a combination of Descemet stripping and automated endothelial keratoplasty and cataract surgery.

Cite

CITATION STYLE

APA

Hsieh, Y. C., Chiang, C. C., & Tsai, Y. Y. (2020). Long-term observation of graft thickness and shape in Descemet stripping and automated endothelial keratoplasty. European Journal of Ophthalmology, 30(1), 155–161. https://doi.org/10.1177/1120672119826004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free