Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients

53Citations
Citations of this article
161Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Eadyn), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure.Methods: We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo®monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%.Results: Before fluid infusion, Eadynwas significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Eadyn(r2= 0.83; P < 0.0001). The only predictor of MAP increase was Eadyn(area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Eadynvalue >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%).Conclusions: Functional assessment of arterial tone by Eadyn, measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation. © 2011 Monge García et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

García, M. I. M., Cano, A. G., & Romero, M. G. (2011). Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Critical Care, 15(1). https://doi.org/10.1186/cc9420

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free