A simple, sensitive, economic and specific reverse phase liquid chromatographic method was developed for the simultaneous estimation of Emtricitabine and Ritonavir in bulk drug. Chromatographic conditions consisted of C-18 Column (Shim-pack) 250 x 4.6 mm, particle size 5 µm , mobile phase combination of methanol and water (80:20), flow rate 1ml per minutes, run time 15 minutes and UV detection at 251nm. . The retention time for Emtricitabine and Ritonavir were found to be 3.25 and 7.8 min and average percentage recoveries 99.42% and 99.63% respectively. The validation parameters were found to comply with ICH guidelines. These methods can be further employed in future for the routine determination of Emtricitabine and Ritonavir in bulk drug and formulation. Keyword: Emtricitabine, Ritonavir, RP-HPLC, accuracy and linearity.
CITATION STYLE
Kapoor, A., Ankalgi, A. D., Thakur, U., Pandit, V., & Ashawat, M. S. (2020). Method Development and Validation for Multicomponent Analysis of Emtricitabine and Ritonavir in Bulk Drug by RP-HPLC. Journal of Drug Delivery and Therapeutics, 10(6), 137–144. https://doi.org/10.22270/jddt.v10i6.4400