Abstract

VNIIOFI carries out works on realization of independent methods for realization of the total spectral radiant flux (TSRF) of incoherent optical radiation sources -reference high-temperature blackbodies (BB), halogen lamps, and LED with quasi-Lambert spatial distribution of radiance. The paper describes three schemes for measuring facilities using photometers, spectroradiometers and computer-controlled high class goniometer. The paper describes different approaches for TSRF realization at the VNIIOFI National radiometric standard on the basis of high-temperature BB and LED sources, and gonio-spectroradiometer. Further, they are planned to be compared, and the use of fixed-point cells (in particular, based on the high-temperature δ(MoC)-C metal-carbon eutectic with a phase transition temperature of 2583 C corresponding to the metrological optical "source-A") as an option instead of the BB is considered in order to enhance calibration accuracy.

Cite

CITATION STYLE

APA

Ivashin, E., Lalek, J., Rybczyński, A., Ogarev, S., Khlevnoy, B., Dobroserdov, D., & Sapritsky, V. (2018). Methods of total spectral radiant flux realization at VNIIOFI. In Journal of Physics: Conference Series (Vol. 972). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/972/1/012011