This study explored the seismic response of a house supporting base sides with a polymeric displacement control material and by magnetically levitating the foundation base. In this paper, we explore the possibility and efficacy of a seismic-isolated detached house as described above from both a shaking table experiment of model and three-dimensional finite element analysis. The seismic-isolated model showed stable response and its acceleration response was significantly reduced compared to the base-fixed model in the shaking table test. Three-dimensional finite element analysis was possible to simulate the experimental results. In the seismic response analysis of a full-scale detached house, the seismic-isolated model showed response reduction and its residual displacement was smaller than that of the sliding-base isolation model.
Mendeley helps you to discover research relevant for your work.
CITATION STYLE
Miyamoto, Y., Nakano, T., Shimamura, A., & Sho, K. (2022). Seismic Response of Magnetically Levitated House. Open Journal of Earthquake Research, 11(01), 1–17. https://doi.org/10.4236/ojer.2022.111001