NT-pro-BNP as marker for cardiac strain that may be caused by high-output arteriovenous shunting in a haemodialysis patient. A case report

6Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: An arteriovenous fistula (AVF) is the first choice when considering access for haemodialysis (HD). When a forearm AVF fails an upper arm AVF is a frequent subsequent dialysis access option. The latter may cause cardiac strain. NT-pro-B-type natriuretic peptide (NT-NT-proBNP) is a marker used to estimate volume overload and cardiac strain. This case report shows the benefit of using longitudinal individual follow-up of pre-dialysis NT-proBNP in clinical practice to detect changes in cardiac condition that may be due to high-output AVF. Case presentation: An 18 years old patient performed HD via an upper arm AVF before he was admitted to our unit. NT-proBNP was above the upper detection level of 70,000 ng/L. Echocardiography revealed a left-ventricular cardiac insufficiency. Interdialytic weight gain (IDWG) was above 5%. He was instructed to lower fluid intake and IDWG towards 2%. Four months later NT-proBNP surpassed 70,000 ng/L again. Flow in the brachial artery was at 3034 ml/min. Reconstructive surgery of the AVF did not reduce flow and NT-proBNP in the long run. Clinically, he worsened to NYHA class III-IV. It was decided to close the upper arm AVF and to replace it with a lower arm AVF leading to a reduced artery flow of 1344 mL/min. The clinical condition successively recovered and NT-proBNP decreased to 7000 ng/L. Conclusions: Pre-dialysis NT-proBNP should be considered as a suitable routine marker for cardiac strain such as caused by high-output AVF besides variables such as IDWG. Brachial artery flow besides AVF flow measurement is helpful.

Cite

CITATION STYLE

APA

Wärja, M., Laveborn, E., Ott, M., Jonsson, A. P., & Stegmayr, B. (2020). NT-pro-BNP as marker for cardiac strain that may be caused by high-output arteriovenous shunting in a haemodialysis patient. A case report. BMC Nephrology, 21(1). https://doi.org/10.1186/s12882-020-02195-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free