Quality control of injection molded eyewear by non-contact deflectometry

2Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Occupational eye wear such as safety spectacles are manufactured by injection molding techniques. Testing of the assembled safety spectacle lenses in transmission is state of the art, but there is a lack of surface measurement systems for occupational safety lenses. The purpose of this work was to validate a deflectometric setup for topography measurement, detection of defects and visualization of the polishing quality, e.g. casting indentations or impressions, for the production process of safety spectacles. The setup is based on a customized stereo phase measuring deflectometer (PMD), equipped with 3 cameras with f'1,2 = 16 mm and f'3 = 8.5 mm and a specified measurement uncertainty of ± 3 μm. Sixteen plastic lenses and 8 corresponding injection molds from 4 parallel cavities were used for validation of the deflectometer. For comparison an interferometric method and a reference standard (

Cite

CITATION STYLE

APA

Speck, A., Zelzer, B., Langenbucher, A., & Eppig, T. (2014). Quality control of injection molded eyewear by non-contact deflectometry. Journal of the European Optical Society, 9. https://doi.org/10.2971/jeos.2014.14027