Management of oxygen saturation monitoring in preterm newborns in the NICU: the Italian picture

10Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Although many studies emphasize the importance of using oxygen saturation (SpO2) targets in the NICUs, there is a wide variability in used saturation ranges among centers. Primary aim was to draw a representative picture on how the management of oxygen monitoring is performed in the Italian NICUs. Second aim was to identify healthcare-professionals related factors associated with oxygen targeting in the preterm population. Methods: Cross-sectional study with data collection via an electronic survey form. A questionnaire containing pre-piloted and open questions on monitoring and management of the SpO2 was administered to neonatologists across the network of the Italian Society of Neonatology. The questions focused on: the infrastructure, specific training, healthcare professionals and patients-related factors. The results of the survey were anonymously collected, summarized and analyzed. Results: Out of 378 questionnaires, 93 were correctly filled. Thirty-six different SpO2 ranges were observed. Centers using written standard operating procedures on oxygen management and SpO2 monitoring maintained a correct average range of SpO2 90–95%, avoided hyperoxia and reconsidered saturation targets in relation to comorbidities. 39.8% of responders disabled alarms during neonatal care. One center used biomarkers for complete monitoring of neonatal oxygenation status. Conclusions: There is considerable variation in SpO2 targets for preterm infants in the Italian NICUs. Standard operating procedures and specific training for health care personnel are the main factors playing a role for the correct maintenance of the recommended oxygen targets in preterms.

Author supplied keywords

Cite

CITATION STYLE

APA

Perrone, S., Giordano, M., De Bernardo, G., Lugani, P., Sarnacchiaro, P., Stazzoni, G., … Laschi, E. (2021). Management of oxygen saturation monitoring in preterm newborns in the NICU: the Italian picture. Italian Journal of Pediatrics, 47(1). https://doi.org/10.1186/s13052-021-01050-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free