Effectiveness of Using a Gelatine-Based Model in Ultrasonography-guided Jugular Central venous Catheter Placement Training: A Randomised Clinical Trial

0Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

Abstract

Objective: To evaluate the effectiveness of using a gelatine-based model, that can be prepared easily and at a low cost, compared to training without a model in ultrasonography (USG) guided internal jugular venous catheter placement training. Study Design: An open-label, randomised clinical trial. Place and Duration of Study: (UHS) Izmir Bozyaka Training and Research Hospital, Izmir, Turkey, from 1st to 30th July 2019. Methodology: Analysis was conducted with the data of 48 participants (resident physicians-RP). Group 1 (n: 26) received imaging training with USG on a human subject and then performed needle insertion training on the gelatine-based jugular vein model with the USG guidance. Group 2 (n: 22) received the same imaging training with USG but did not perform needle insertion training. Evaluation of the participants included successful long axis vein imaging time, successful in-plane needle imaging, number of changes in needle angles, the total number of punctures, successful vein puncture time, successful catheterization time, and catheterization success with the gelatine-based test manikin. Results: Comparison of the rates of successful in-plane needle imaging (Group 1: 92.3%, Group 2: 59.1%; p = 0.006), catheterization success (Group 1: 92.3%, Group 2: 59.1%; p = 0.006), successful catheterisation time (Group 1: 77.5 sec, Group 2: 152.5 sec; p = 0.026), and total complications (Group 1: 3.8%, Group 2: 31.8%; p = 0.010) demonstrated that the model-trained RPs were significantly more successful. Conclusion: The study results suggest that the use of a gelatine-based model in USG-guided central jugular vein catheterisation training can be an effective method to reduce complications.

Cite

CITATION STYLE

APA

Tekgul, Z. T., Yesilnacar, C., Bilgin, M. U., & Ozkarakas, H. (2022). Effectiveness of Using a Gelatine-Based Model in Ultrasonography-guided Jugular Central venous Catheter Placement Training: A Randomised Clinical Trial. Journal of the College of Physicians and Surgeons Pakistan, 32(5), 596–601. https://doi.org/10.29271/jcpsp.2022.05.596

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free