Technical note: Gold marker implants and high-frequency jet ventilation for stereotactic, single-dose irradiation of liver tumors

19Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

With reference to radiosurgery of the liver, we describe techniques designed to solve the methodological problem of striking targets subject to respiratory motion with the necessary precision. Implanting a gold marker in the vicinity of the liver tumor was the first step in ensuring the reproducibility of the isocenter's position. An 18-karat gold rod measuring 1.9 × 3 mm was implanted approximately 2 cm from the edge of the tumor as this was displayed in the spiral, thin-slice CT with contrast media. Both the implantation of the marker and the required, CT-controlled biopsy of the liver tumor can be achieved simultaneously with the same puncture needle. The efficiency of high-frequency jet ventilation (HFJV) in neutralizing the targeted organ's respiratory motion during stereotactic single-dose irradiation was evaluated. The procedure was carried out on ten patients without any complications. In the time between treatment planning and irradiation (3 days), no significant marker migration was observable. In all cases, the gold marker (volume: 7.5 mm3) was readily observable in the treatment beam using portal imaging. HFJV provided reliable immobilization. The liver motion in each anesthetized patient was limited to under 3.0 mm in all directions. Thus, the correct field settings and target reproducibility were able to be analyzed and documented during the irradiation. The combination of marker and HFJV enables the determination of stereotactic coordinates directly related to the liver itself and, in this way, stereotactic radiation treatment of liver tumors is freed from the uncertainties involved in orientation to bony landmarks, in respiratory motion, and in changes of position in the stereotactic body frame. The method is feasible and can improve the accuracy of stereotactic body radiation therapy. ©Adenine Press (2005).

Cite

CITATION STYLE

APA

Fritz, P., Kraus, H. J., Dölken, W., Mühlnickel, W., Müller-Nolte, F., & Hering, W. (2006). Technical note: Gold marker implants and high-frequency jet ventilation for stereotactic, single-dose irradiation of liver tumors. Technology in Cancer Research and Treatment, 5(1), 9–14. https://doi.org/10.1177/153303460600500102

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free