Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients: Implications for clinical practice

28Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Changes in high sensitivity cardiac troponin-T (hs-cTnT) concentrations may reflect either acute myocardial injury or biological variation. Distinguishing between these entities is essential to accurate diagnosis, however, the biological variation of hs-cTnT in dialysis population is currently unknown. We sought to estimate the within- and between-person coefficients of variation of hs-cTnT in stable dialysis patients, and derive the critical difference between measurements needed to exclude biological variation with 99% confidence. Methods: Fifty-five prevalent haemo- and peritoneal-dialysis patients attending two metropolitan hospitals were assessed on 10 consecutive occasions; weekly for 5 weeks then monthly for 4 months. Assessments were conducted at the same dialysis cycle time-point and entailed hs-cTnT testing, clinical review, electrocardiography, and bioimpedance spectroscopy. Patients were excluded if they developed clinical or physiological instability. Results: In total 137 weekly and 114 monthly hs-cTnT measurements from 42 stable patients were analysed. Respective between- and within-person coefficients of variation were 83% and 7.9% for weekly measurements, and 79% and 12.6% for monthly measurements. Within-person variation was unaffected by dialysis modality or cardiac co-morbidity. The bidirectional 99% reference change value was -25% and +33% for weekly measurements, and -37% and +58% for monthly measurements. Conclusions: The between-person variation of hs-cTnT in the dialysis population is markedly greater than within-person variation indicating that hs-cTnT testing is best applied in this population using a relative change strategy. An increase of 33% or a reduction of 25% in serial hs-cTnT concentrations measured at weekly intervals excludes change due to analytical and biological variation alone with 99% confidence.

Author supplied keywords

Cite

CITATION STYLE

APA

Fahim, M. A., Hayen, A. D., Horvath, A. R., Dimeski, G., Coburn, A., Tan, K. S., … Hawley, C. M. (2015). Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients: Implications for clinical practice. Clinical Chemistry and Laboratory Medicine, 53(5), 715–722. https://doi.org/10.1515/cclm-2014-0838

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free