Optimized temporary bi-ventricular pacing improves haemodynamic function after on-pump cardiac surgery in patients with severe left ventricular systolic dysfunction: A two-centre randomized control trial

8Citations
Citations of this article
80Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: Optimized temporary bi-ventricular (BiV) pacing may benefit heart failure patients after on-pump cardiac surgery compared with conventional dual-chamber right ventricular (RV) pacing. An improvement in haemodynamic function with BiV pacing may reduce the duration of 'Level 3' intensive care. Methods: Thirty-eight patients in sinus rhythm, ejection fraction ≤35%, undergoing on-pump surgical revascularization, valve surgery or both were enrolled in this study. Before closing the sternum, temporary epicardial pacing wires were attached to the right atrium, RV outflow tract and basal posterolateral wall of the left ventricle. Patients were randomly assigned to postoperative BiV pacing with the optimization of the atrio- (AV) and inter-ventricular (VV) pacing intervals (Group 1) or conventional dual-chamber right AV pacing (Group 2). The primary end-point was the duration of 'Level 3' intensive care. Secondary end-points included cardiac output which was measured by thermodiluation at admission to the intensive care unit and at 6 and 18 h later, in five different pacing modes. Results: The duration of 'Level 3' care was similar between groups (40 ± 35 vs 54 ± 63 h; Group 1 vs 2; P = 0.43). Cardiac output was similar in all pacing modes at baseline. At 18 h, cardiac output with BiV pacing (5.8 l/min) was 7% higher than atrial inhibited (5.4 l/min) and 9% higher than dual-chamber RV pacing (5.3 l/min; P = 0.02 and 0.001, respectively). Optimization of the VV interval produced a further 4% increase in cardiac output compared with baseline settings (P = 0.005). Conclusions: Postoperative haemodynamic function may be enhanced by temporary BiV pacing of high-risk patients after on-pump cardiac surgery. © The Author 2012.

Cite

CITATION STYLE

APA

Russell, S. J., Tan, C., O’Keefe, P., Ashraf, S., Zaidi, A., Fraser, A. G., & Yousef, Z. R. (2012). Optimized temporary bi-ventricular pacing improves haemodynamic function after on-pump cardiac surgery in patients with severe left ventricular systolic dysfunction: A two-centre randomized control trial. European Journal of Cardio-Thoracic Surgery, 42(6). https://doi.org/10.1093/ejcts/ezs492

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free