Electronic portal imaging

5Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

In our institute, we have developed an electronic portal imaging system based on a matrix of 256 x 256 ionisation chambers. By improvements to the electronics, the system produces images with the same quality as the original system but 3-10 times faster. Software for automatic image analysis has been applied to more than 10000 images over the last two years. Using an off-line correction strategy, the systematic patient set-up error has been limited to 5 mm or less for 98% of the patients treated for prostate cancer.

Cite

CITATION STYLE

APA

Van Herk, M., Bel, A., Gilhuijs, K. G. A., Lebesque, J. V., Van Dalen, A., Van Der Ven, P., & Vijlbrief, R. (1995). Electronic portal imaging. In Bulletin du Cancer (Vol. 82). https://doi.org/10.32388/1foxaf