Abstract

Purpose: Pulse oximeter accuracy is important for the quality and safety of patient care. Methodological errors occurring during pulse oximeter accuracy studies can confound results. One potential source of error during pulse oximeter comparison studies is optical interference due to sensor-to-sensor crosstalk. Optical crosstalk can occur whenever pulse oximeter sensors are tested in close proximity of one another, as occurs during pulse oximeter comparison studies. Methods: This publication represents the first comprehensive review of sensor-to-sensor crosstalk and other forms of optical interference during pulse oximeter comparison studies. A review of the published literature was undertaken to elucidate the mechanism of optical crosstalk, along with other forms of optical interference, and a solution (shielding) is offered. Results: When pulse oximeter sensors are placed close to each other, as occurs during comparison studies, the red and near-infrared light used can also enter an adjacent sensor and lead to error. Pulse oximeter manufacturers have designed systems to reject some forms of optical interference, such as ambient light. However, light emanating from adjacent sensors during comparison studies can cause artifact, and this can be exacerbated by sensor malposition. Proper sensor placement and use of optical shielding are the best solutions to prevent crosstalk. Conclusions: Crosstalk and other forms of optical interference can corrupt pulse oximeter readings. Proper sensor placement and use of optical shielding of sensors are crucial steps to help protect the integrity of the data. Studies to further characterize crosstalk during pulse oximeter comparison studies are needed.

References Powered by Scopus

Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations

466Citations
N/AReaders
Get full text

Potential errors in pulse oximetry III: Effects of interference, dyes, dyshaemoglobins and other pigments

186Citations
N/AReaders
Get full text

The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition

58Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Racial effects on masimo pulse oximetry: impact of low perfusion index

3Citations
N/AReaders
Get full text

Response to: 'Randomised crossover study on pulse oximeter readings from different sensors in very preterm infants' by Sharma et al

1Citations
N/AReaders
Get full text

Patent and Bibliometric Analysis of the Scientific Landscape of the Use of Pulse Oximeters and Their Prospects in the Field of Digital Medicine

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kyriacou, P. A. (2023, December 1). Optical crosstalk and other forms of light interference in pulse oximeter comparison studies. Journal of Clinical Monitoring and Computing. Springer Science and Business Media B.V. https://doi.org/10.1007/s10877-023-01060-y

Readers over time

‘23‘24‘2502468

Readers' Seniority

Tooltip

Lecturer / Post doc 1

50%

Researcher 1

50%

Readers' Discipline

Tooltip

Chemistry 2

67%

Medicine and Dentistry 1

33%

Save time finding and organizing research with Mendeley

Sign up for free
0