Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy

15Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Despite combined modality treatment involving surgery and radiotherapy, a relevant proportion of skull-base chordoma and chondrosarcoma patients develop a local recurrence (LR). This study aims to analyze patterns of recurrence and correlate LR with a detailed dosimetric analysis. Methods: 222 patients were treated with proton radiotherapy for chordoma (n = 151) and chondrosarcoma (n = 71) at the PSI between 1998 and 2012. All patients underwent surgery, followed by pencil-beam scanning proton therapy to a mean dose of 72.5 ± 2.2GyRBE. A retrospective patterns of recurrence analysis was performed: LR were contoured on follow-up MRI, registered with planning-imaging and the overlap with initial target structures (GTV, PTVhigh-dose, PTVlow-dose) was calculated. DVH parameters of planning structures and recurrences were calculated and correlated with LR using univariate and multivariate cox regression. Results: After a median follow-up of 50 months, 35 (16%) LR were observed. Follow-up MRI imaging was available for 27 (77%) of these recurring patients. Only one (3.7%) recurrence was located completely outside the initial PTV (surgical pathway recurrence). The mean proportions of LR covered by the initial target structures were 48% (range 0–86%) for the GTV, 70% (range 0–100%) for PTVhigh and 83% (range 0–100%) for PTVlow. In the univariate analysis, the following DVH parameters were significantly associated with LR: GTV(V < 66GyRBE, p = 0.01), GTV(volume, p = 0.02), PTVhigh(max, p = 0.02), PTVhigh(V < 66GyRBE, p = 0.03), PTVhigh(V < 59GyRBE, p = 0.02), PTVhigh(volume, p = 0.01) and GTV(D95, p = 0.05). In the multivariate analysis, only histology (chordoma vs. chondrosarcoma, p = 0.01), PTVhigh(volume, p = 0.05) and GTV(V < 66GyRBE, p = 0.02) were independent prognostic factors for LR. Conclusion: This study identified DVH parameters, which are associated with the risk of local recurrence after proton therapy using pencil-beam scanning for patients with skull-base chordoma and chondrosarcoma.

Cite

CITATION STYLE

APA

Basler, L., Poel, R., Schröder, C., Bolsi, A., Lomax, A., Tanadini-Lang, S., … Weber, D. C. (2020). Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy. Radiation Oncology, 15(1). https://doi.org/10.1186/s13014-020-01711-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free