Joint intensity inhomogeneity correction for whole-body MR data

4Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Whole-body MR receives increasing interest as potential alternative to many conventional diagnostic methods. Typical whole-body MR scans contain multiple data channels and are acquired in a multi-station manner. Quantification of such data typically requires correction of two types of artefacts: different intensity scaling on each acquired image stack, and intensity inhomogeneity (bias) within each stack. In this work, we present an all-in-one method that is able to correct for both mentioned types of acquisition artefacts. The most important properties of our method are: 1) All the processing is performed jointly on all available data channels, which is necessary for preserving the relation between them, and 2) It allows easy incorporation of additional knowledge for estimation of the bias field. Performed validation on two types of whole-body MR data confirmed superior performance of our approach in comparison with state-of-the-art bias removal methods. © 2013 Springer-Verlag.

Cite

CITATION STYLE

APA

Dzyubachyk, O., Van Der Geest, R. J., Staring, M., Börnert, P., Reijnierse, M., Bloem, J. L., & Lelieveldt, B. P. F. (2013). Joint intensity inhomogeneity correction for whole-body MR data. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (Vol. 8149 LNCS, pp. 106–113). https://doi.org/10.1007/978-3-642-40811-3_14

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free